Table 2 Clinical and angiographic outcomes

From: Safety and efficacy of stent-assisted coiling for acutely ruptured wide-necked intracranial aneurysms: comparison of LVIS stents with laser-cut stents

Outcomes LVIS stent group laser-cut stent group P value
Immediate embolization result
 Raymond I 91(64.1) 47(50.5) 0.039
 Raymond II–III 51(35.9) 46(49.5)
Clinical outcome at discharge
 mRS score 0–2 125(88.0) 79(84.9) 0.495
 mRS score 3–6 17(12.0) 14(15.1)
Angiographic follow-up
 Complete occlusion 101(92.7) 58(80.6) 0.078
 Improvement 2(1.8) 5(6.9)
 Stability 2(1.8) 2(2.8)
 Recurrence 4(3.7) 7(9.7)
Clinical follow-up*
 mRS score 0–2 114(89.1) 76(88.4) 0.875
 mRS score 3–6 14(10.9) 10(11.6)
Clinical follow-up†
mRS score 0–2 114(83.8) 76(84.4) 0.901
mRS score 3–6 22(16.2) 14(15.6)
  1. *Excluding patients who died at discharge
  2. †Including patients who died at discharge
  3. Unless indicated otherwise, data are presented as the number of patients (%)